20% off

KSD-01F D 65°C NORMAL CLOSED TEMPERATURE THERMOSTAT TO-220

80 100 20% off

Select Qty Discount Price per piece

1 - 51 0% Rs 80

51 - 101 10% Rs 72

101 - 501 20% Rs 64

501 - 1001 30% Rs 56

1001 - 5001 40% Rs 48

5001 - 1000001 60% Rs 32


Description

  1. Product Name: Temperature Control Switch
  2. Product Model: KSD01-F
  3. Part No. : KSD-01F D 65°C
  4. Switch Type: Normally Closed
  5. Temperature: 65°C
  6. Size: 3*1.1*0.6cm

Inquiry  
Deliver to

KSD-01F Series Temperature Relay Structural features: Advanced compression spring structure design, high-sensitivity sudden jump process bimetal forming. It belongs to the temperature-fixed SPST type bimetal instantaneous temperature controller. Adopt TO-220 standard package. Scope of application: It is used for temperature control and overheat protection in electrical equipment, electronic products, instruments, meters, power supplies, power amplifiers, household appliances and circuit boards. Model Nomenclature KSD-01F15D (Example) Temperature Relay Ultra-Small Dash Product Serial Number Enclosed Action Temperature Contact Form Action Forms Action forms 2. A group of dynamic break electric shock (D means normally closed), the high contact with the temperature rise is disconnected, and the electric shock is closed with the temperature decrease.The terminals are lead-free. Environmental certification meets environmental requirements Basic performance parameters Electrical parameters Life cycle Working voltage Load current >10,000 48VDC 1 >10,000 120VAC 1 100,000 5VDC 0.020 100,000 5VDC 0.001 Temperature temperature characteristics Operating temperature: 65±5?; Recovery temperature: 48±7?; Test Method Install the thermostat on the test fixture and place it in the test area for testing. Use air as the heat transfer medium, and place a thermometer or temperature sensor in the temperature measurement. In the temperature range where the temperature enters the product action, the lower limit of the recovery temperature minus 3K to the product action, and the upper limit of the recovery temperature plus 3K, the temperature rise and fall rate should be ensured not greater than 1K/min, during which the air in the temperature measurement area must be checked Stir thoroughly to make the temperature distribution uniform: the temperature uniformity in the temperature measurement area is within 0.4K. Resistance between terminals Initial value: ?50m?; After life: ?500m?; Test load: DC 6V, 10mA. Under standard atmospheric conditions, the insulation resistance is tested with a DC500V insulation resistance meter and the rated voltage is greater than or equal to 100M?; under standard atmospheric conditions, the electrical strength is under standard atmospheric conditions. Arc, flashover, etc. Use ambient temperature -25c?~+180c? Grounding method Connect to the equipment grounding metal through the outer metal plate of the temperature thermostatReliability parameters Experimental conditions 1. Ambient temperature 20?5c?; 2. Ambient relative humidity 60%~70%; 3. The power supply should be a sine wave power supply with rated voltage and rated frequency of 50Hz.  If there is no objection to the experimental results, the experiment can be carried out according to the following conditions: 4. Ambient temperature 5~20c?; 5. Ambient relative humidity 45%~85%; 6. The power supply is an AC power supply close to a sine wave.  : Working life Test method The thermostat is subjected to electric shock opening and closing test by heating and cooling under the rated load. The maximum cycle frequency is ?6 times/min, and each opening and closing is regarded as a cycle.  After the product has undergone the specified number of durability tests, the performance indicators should meet the following requirements: 1. The operating temperature is below 100c?, plus ?5c? for the initial value of the test, and ?5% above 100c? 2. Under standard atmospheric conditions  , use DC500V insulation resistance meter to test ?100M? with rated voltage.  3. Under standard atmospheric conditions, apply 1000V 50Hz AC voltage between the terminal and the ground for 1min, without breakdown, arcing, and flashover.  Resistant to low temperature, high temperature and cold and thermal shock The product sample is placed in a low temperature box of -20c? and kept at a constant temperature for 1h, taken out and placed for 2h;  The product sample is placed in a low temperature box of -20c? and kept at a constant temperature for 0.5h, taken out and placed in a room temperature environment for 5min, and then placed in a high temperature box of 150c? and kept at a constant temperature for 0.5h, taken out and placed in a room temperature environment for 5min, and so on for 5 times  cycle.  After the test is completed, the product performance indicators should meet the following requirements: 1. Add ?5c? to the initial test value for the operating temperature below 100c?, and ?5% above 100c? 2. Under standard atmospheric conditions, use DC500V insulation  The ohmmeter tests ?100M? at rated voltage.  3. Under standard atmospheric conditions, apply 1000V 50Hz AC voltage between the terminal and the ground for 1min, without breakdown, arcing, and flashover.  Moisture resistance After placing the product sample in a constant temperature and humidity box with a temperature of 40?5c? and a relative humidity of 90~95% for 48 hours according to GJB360.6, the product sample should meet the following performance indicators: 1. The operating temperature is below 100c?  Add ?5c? to the allowable deviation of the initial test value, ?5% above 100c? 2. Under standard atmospheric conditions, use a DC500V insulation resistance meter to test ?100M? at rated voltage.  3. Under standard atmospheric conditions, apply 1000V 50Hz AC voltage between the terminal and the ground for 1min, without breakdown, arcing, and flashover.  Vibration resistance The product sample is rigidly connected and fixed on the vibration test bench, relative to the upper and lower, front and rear, left and right directions, avoiding the upper and lower limit of the product's operating temperature ?10c?, with a frequency of 20~25Hz and an amplitude of 3mm for a back and forth time of 5min, which lasted 1h  .  After the test, the product sample should meet the following performance indicators: 1. Add ?5c? to the initial test value for the operating temperature below 100c?, and ?5% above 100c? 2. Under standard atmospheric conditions, adopt DC500V insulation  The ohmmeter tests ?100M? at rated voltage.  3. Under standard atmospheric conditions, apply 1000V 50Hz AC voltage between the terminal and the ground for 1min, without breakdown, arcing, and flashover.
Weight 2.1 kg
Dimensions 122 × 145 × 321 cm

You may also like…

View All